中文

HY2142-DA6G Secondary Protection IC (Fuse Blow)

HY2142-DA6G Secondary Protection IC (Fuse Blow)

HY2142-DA6G is a secondary protection IC (fuse-blow type) from SIS (formerly HYCON Technology), supplied in a DFN2.0*2.0 package (4 cells). It is a secondary (backup) overcharge protector for multi-cell Li-ion packs: when a cell stays above the overcharge threshold it drives an external fuse to open the circuit permanently, adding a redundant safety layer in case the primary protection fails. Key thresholds: overcharge 4.5 V.

HY2142-DA6G specifications

BrandSIS (formerly HYCON Technology)
CategorySecondary Protection IC (Fuse Blow)
PackageDFN2.0*2.0
Cell count4 cells
StatusActive
Overcharge detection voltage (VCU)4.5 V

Detailed parameters

ParameterValue
Overcharge Release Voltage (VCRn)4.100 V
Overcharge Detection Delay Time (TOCn)6.0s
Overcharge Release Delay Time (TCRn)64ms
Reset Delay Time of Overcharge Detection Counter (TDTR)<0.6ms

Typical applications

HY2142-DA6G is used in power tools, e-bikes, energy storage systems, medical and industrial battery packs that require a redundant protection layer.

Selection notes

Check the overcharge trigger voltage accuracy, the detection delay (TCU), the supported cell count (2S–4S or more) and the fuse drive capability, and coordinate the thresholds with the primary protection IC.

Other HY2142 variants

Price, samples and datasheets
Well-buy Technology is an authorized distributor of SIS (formerly HYCON Technology) in mainland China. Email ivan.chan@well-buy.com with the part number, quantity and application — we reply in English or Chinese. Datasheet download is available on the Chinese product page.